C-0978 - The Experience of Dynamic CT-perfusion Control in Endovascular Treatment of Patients with Multifocal Stenotic and Occlusion Lesions of Cerebral Artery

Y. Cherednychenko, N. A. Cherednychenko, L. Dzyak, M. Zorin, A. Miroshnychenko; Dnipropetrovsk/UA Type: Scientific Exhibit
Area of Interests: Head and neck, Interventional vascular, Arteries / Aorta
Imaging Techniques: Catheter arteriography, CT
Procedures: Stents, Efficacy studies, Angioplasty
Special Focuses: Arteriosclerosis, Hemodynamics / Flow dynamics
Add poster to my schedule In your schedule (remove)

Direct link to access the poster (click here)

Aims and objectives: Evaluating of the role of dynamic CT- brain perfusion control for determination of necessity, efficiency and sufficiency of endovascular treatment of the multifocal stenotic and occlusion lesions of cerebral artery. 

Methods and materials: The choice of staging and capacity of endovascular treatment of multifocal stenotic and occlusion lesions of cerebral arteries depends on degree of perfusion deficit in different arterial basins and changes of these parameters after each endovascular session. 74 patients with multifocal stenotic and[...]

Results: The choice of sequence, staging and capacity of endovascular treatment of multifocal stenotic and occlusion lesions of cerebral arteries depended on degree of brain perfusion deficit and compensatory reactions in different arterial basins and changes of these parameters after each endovascular sessi[...]

Conclusion: The usage of dynamic CT-brain perfusion control allows to define optimal  sequence, staging and volume of endovascular treatment of multifocal stenotic and occlusion lesions of cerebral arteries. Endovascular methods of treatment of multifocal stenotic and occlusion lesions of cerebral arteries[...]

Personal information:

References: 1. Wintermark M, Maeder P, Thiran JP, Schnyder P, Meuli R. Quantitative assessment of regional cerebral blood flow by perfusion CT studies at low injection rates: a critical review of the underlying theoretical models. // Eur Radiol 2001, v. 11, P 1220_1230. 2. Wintermark M, Reichhart M, Thiran JP, [...]